2003 4RUNNER from Apr. ’03 Prod. (OM35820U)
Positive
terminal
(“+” mark)
Jumper cable
Positive terminal
(“+” mark)
Booster
battery
Discharged battery
4. Make the cable connections in the or-
der a, b, c, d.
a. Connect the clamp of the positive
(red) jumper cable to the positive (+)
terminal on the discharged battery.
b. Connect the clamp at the other end
of the positive (red) jumper cable to
the positive (+) terminal on the booster
battery.
Discharged battery
Booster battery
Negative
terminal
(“–” mark)
Jumper cable
c. Connect the clamp of the negative
(black) jumper cable to the negative (–)
terminal on the booster battery.
d. Connect the clamp at the other end
of the negative (black) jumper cable to
a solid, stationary, unpainted, metallic
point of the vehicle with the discharged
battery.
The recommended connecting points
are shown in the following illustrations:
Connecting point for 1GR–FE engine
Connecting point for 2UZ–FE engine