EasyManua.ls Logo

TP-Link JetStream T2700G-28TQ - Page 18

TP-Link JetStream T2700G-28TQ
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
13
Stackable L2+/L3 Managed Switch
Installation
2. Log on to the GUI of each switch, go to Stack
Stack Management
Stack
Cong page to enable the stack mode of port M1 and M2 (port 1/1/1 and 1/1/2 on
the GUI). Remember to click Save Cong after the configuration.
3. Power off the switches, and then connect a 10G SFP+ cable (TXC432-CU1M/TXC432-
CU3M of TP-LINK for example) between each pair of Interface Cards among the
switches, thus forming a ring topology as the following figure shows. A ring topology
system provides redundancy and resiliency to the stack.
M1
SFP+
M2
SFP+
CLASS 1 LASER PRODUCT
TX432
Module
Power
PS OK
Fault
PSM150-AC
100-240V~ 50/60Hz 2.5A
M1
SFP+
M2
SFP+
CLASS 1 LASER PRODUCT
TX432
Module
Power
PS OK
Fault
PSM150-AC
100-240V~ 50/60Hz 2.5A
M1
SFP+
M2
SFP+
CLASS 1 LASER PRODUCT
TX432
Module
Power
PS OK
Fault
PSM150-AC
100-240V~ 50/60Hz 2.5A
M1
SFP+
M2
SFP+
CLASS 1 LASER PRODUCT
TX432
Module
SFP+ cable
Figure 3-7 Stacking Using Interface Card
4. Power on the switches, then the switches will automatically select a master unit. The
Master LED of the selected switch will be on.
5. You can access to any member of the stack via Web/SSH/Telnet/Console connection,
thus to manage all the switches in the stack.
Caution: In the process of using TP-LINK SFP+ Cables, please never bend them into
a radius of 45mm (1.77 inch) or less, because it may permanently damage the SFP+
Cables.

Other manuals for TP-Link JetStream T2700G-28TQ