Panel Layout
Input: 100–240 V ~ 50/60 Hz 1.8 A (Max)
Output: 12 V, 6.25 A (Max)
Ripple & Noise: < 180 mV (0˚C to 50˚C);
< 250 mV (-10˚C to 0˚C)
AC Power Supply
Power, FANLED
Dimensions
(W×D×H)
Operation Temperature TL-MC1400: 0˚C to 40˚C (32˚F to 104˚F)
TL-FC1420: 0˚C to 50˚C (32˚F to 122˚F)
Storage Temperature -40˚C to 70˚C (-40˚F to 158˚F)
Storage Humidity 5% to 90% RH non-condensing
482 × 309 × 86 mm
Operation Humidity 10% to 90% RH non-condensing
Specifications Environmental and Physical Specifications
Specications
Power LED
AC Power Plug
Grounding Terminal FAN
Optional Power Supply Position
LED Explanation
On: Power on
O:
Power o
Power
On: The fans are working properly.
O:
The fans are working abnormally.
FAN
Note:
· An optional AC or DC power supply is available for installation in the optional power supply position.
· The power source should comply with Electrical Energy Source Class 1 (ES1) of IEC 62368-1.
YesHot-swappable
YesOverload Protection
FAN LED
DC Power Output per Slot
TL-MC1400: 9 V/0.6 A
TL-FC1420: 5 V/0.6 A
Safety Information
Keep the device away from water, re, humidity or hot environments.
Do not attempt to disassemble, repair, or modify the device. If you need service, please contact us.
Avoid using this product during an electrical storm. There may be a remote risk of electric shock from
lightning.
The label is placed on the bottom surface of the product.
Place the device with its bottom surface downward.
The socket-outlet shall be installed near the equipment and shall be easily accessible.
Plug the product into the wall outlets with earthing connection through the power supply cord or plug.
EU Declaration of Conformity
TP-Link hereby declares that the device is in compliance with the essential requirements and other
relevant provisions of directives 2014/30/EU, 2014/35/EU, 2009/125/EC, 2011/65/EU and (EU)2015/863.
The original EU declaration of conformity may be found at https://www.tp-link.com/en/ce.
Please read and follow the above safety information when operating the device. We cannot guarantee
that no accidents or damage will occur due to improper use of the device. Please use this product
with care and operate at your own risk.
In Denmark: Apparatets stikprop skal tilsluttes en stikkontakt med jord som giver forbindelse til
stikproppens jord.
In Finland: Laite on liitettävä suojakoskettimilla varustettuun pistorasiaan
In Norway: Apparatet må tilkoples jordet stikkontakt
In Sweden: Apparaten skall anslutas till jordat uttag