Parameter
ingress-rate —— Specify the bandwidth for receiving packets. Range:1-100000
for the megaport, 1-1000000 for the gigaport.
egress-rate —— Specify the bandwidth for sending packets. Range:1-100000
for the megaport, 1-1000000 for the gigaport.
all | ingress | egress —— Disable the bandwidth limitation function on the
specified packet type. “all indicates the bandwidth limitation on receiving and
sending packets is disabled; ingress indicates the bandwidth limitation on
receiving packets is diabled; egress indicates the bandwidth limitation on
sending packets is disabled.
Command Mode
Interface Configuration Mode (interface gigabitEthernet / interface range
gigabitEthernet)
Example
Configure the ingress-rate as 5120Kbps and egress-rate as 1024Kbps for port 5:
TL-SG3424(config)# interface gigabitEthernet 1/0/5
TL-SG3424(config-if)# bandwidth ingress 5120 egress 1024
clear counters
Description
The clear counters command is used to clear the statistic information of all the
Ethernet ports.
Syntax
clear counters
Command Mode
Global Configuration Mode
Example
Clear the statistic information of all ports
TL-SG3424(config)# clear counters