4 18-CH34D1-8B-EN
Installer’s Guide
NOTE: Ensure termination location clearance di-
mensions as shown in Figure 5. Do not locate the
vent cap directly to the wall surface. A distance of
1" ± 1/2" is required to prevent water accumulating
between the vent ns.
NOTE: If assembly needs to be extended to allow
side wall thickness requirement, the two pipes
supplied in the kit may be replaced by using same
diameter, eld supplied SDR-21, SDR-26, or SCH
40 PVC pipe. Do not extend the 4" pipe (24" as
shipped) to more than 60 in. (See Figure 2). The 4"
pipe may be shortened to 14" minimum.
IMPORTANT:


for installation of through – the – wall vented gas










 




















-






CONCENTRIC VENT
SIDE WALL INSTALLATION
6
COMBUSTION
COMBUSTION AIR
AIR
VENT
VENT
ELBOW
(FIELD
RAIN
CAP
SUPPLIED)
STRAP
(FIELD SUPPLIED)
1” ½” ±
NOTE: FLUE GAS DEGRADATION
The moisture content of the ue gas may have a detrimen-
tal eect on some building materials. This can be avoided
by using the roof or chimney venting option. When wall
venting is used on any surface that can be aected by this
moisture, it is recommended that a corrosion resistance
shield (24 inches square) be used behind the Vent
Terminal. This shield an be made of wood, plastic, sheet
metal, etc. Also, silicone caulk all cracks, seams, and
joints within 3 feet of the Vent Terminal.
NOTE: Two or more installations require a minimum sepa-
ration distance of 12 inches between vent kits.
CONCENTRIC VENT
SIDE WALL
5
MAINTAIN 12 IN
(18 IN. FOR CANADA)
12” MIN TO
OVERHANG
MINIMUM CLEARANCE
ABOVE HIGHEST
ANTICIPATED SNOW
LEVEL OR GRADE
WHICH EVER IS GREATER
VENT
COMBUSTION
AIR
1” ½” ±
NOTE: To prevent the possiblility of condensate freeze-up,
do not install vent kits one above the other.
 


 

