EasyManua.ls Logo

Trane Thermo King ClimaAIRE II - ClimaAIRE I D Controller Specifications

Trane Thermo King ClimaAIRE II
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
26
TK 53050-3-OP-EN
Specifications
APPLICATION
Control of HVAC unit
SETUP TEMPERATURE RANGE 17 °C (63 °F) to 27 °C (80 °F)
Display in °C and °F as firmware option
OPERATING VOLTAGE RANGE 10 - 32 VDC
CURRENT CONSUMPTION Max. 100 mA
OPERATING TEMPERATURE RANGE -30 °C (-22 °F) to 80 °C (176 °F)
CONNECTION RS232 serial connection
CAN bus - CAN0, CAN1
DIMENSION (WxHxD) 187 mm x 57 mm x 60 mm
POWER SUPPLY
Ready for 12 VDC and 24 VDC
INPUTS Interior Temperature Sensor
Freeze Temperature Sensor
Ambient Temperature Sensor
Heating Coil Temperature Sensor
Floor Heating Temperature Sensor
0 - 5 V DC Analog Input
Coil Pressure Switch
Pressure Switch (LPCO, HPCO)
OUTPUTS (0.7 A Low Side Output - 1.0 A High Side
Output)
3 for Blower Speed - LSO - or PWM 20 kHz
Alternator Excitation - LSO
Compressor Clutch - LSO
Boost Pump - LSO
2 for Solenoid Heat Valve (PWM 0.1 Hz) -
HSO
2 for Fresh Air Damper (0 - 50 - 100% or
PWM 1 Hz) - HSO
2 LSO free (2-speed floor blower)
DIAGNOSTIC / PROGRAMMING RS-232, CANDiag software