BAS-SVX46E-EN
17
Figure 9. UC600 application with an XM70/XM90 and multiple expansion modules
A
O
6
UI
14
A
O
5
UI
13
A
O
4
UI
12
A
O
3
UI
11
A
O
2
UI
10
A
O
1
UI
9
B
O
4
B
O
3
B
O
2
B
O
1
RELAYS 0.5 A MAX
IM
C
1
IM
C
P
1
UI
8
UI
7
UI
6
UI
5
UI
4
UI
3
UI
2
UI
1
IMC
+
24
VDC
OUT
+
24
VDC
+
24
VDC
OUT
24
VAC
XFMR
24
VAC
SERVI
C
E
IM
C
RX
TX
ADDRESS
0
1
2
3
4
5
6
7
8
9
x1
0
1
2
3
4
5
6
7
8
9
x10
B
O
4
B
O
3
B
O
2
B
O
1
XM70
XM70
UC600 controller
Red wires removed
24 Vac
24 Vac
24 Vac
A
O
6
UI
14
A
O
5
UI
13
A
O
4
UI
12
A
O
3
UI
11
A
O
2
UI
10
A
O
1
UI
9
B
O
4
B
O
3
B
O
2
B
O
1
RELAYS 0.5 A MAX
IM
C
1
IM
C
P
1
UI
8
UI
7
UI
6
UI
5
UI
4
UI
3
UI
2
UI
1
IMC
+
24
VDC
OUT
+
24
VDC
+
24
VDC
OUT
24
VAC
XFMR
24
VAC
SERVI
C
E
IM
C
RX
TX
ADDRESS
0
1
2
3
4
5
6
7
8
9
x1
0
1
2
3
4
5
6
7
8
9
x10
B
O
4
B
O
3
B
O
2
B
O
1
A
O
6
UI
14
A
O
5
UI
13
A
O
4
UI
12
A
O
3
UI
11
A
O
2
UI
10
A
O
1
UI
9
B
O
4
B
O
3
B
O
2
B
O
1
RELAYS
0
.
5
A MAX
IM
C
1
IM
C
P
1
UI
8
UI
7
UI
6
UI
5
UI
4
UI
3
UI
2
UI
1
IMC
+
24
VDC
LINKOUT
+
24
VDC
+
24
VDC
OUT
24
VAC
MBUS
OUT
24
VAC
XFMR
24
VAC
SERVICE TOOL
SERVI
C
E
LINK
ACT
IM
C
MBUSLINK
RX
TX
U
C
600
ADDRESS
0
1
2
3
4
5
6
7
8
9
x1
0
1
2
3
4
5
6
7
8
9
x10
0
1
2
3
4
5
6
7
8
9
x100
B
O
4
B
O
3
B
O
2
B
O
1
IM
C
IM
C
A
O
6
UI
14
A
O
5
UI
13
A
O
4
UI
12
A
O
3
UI
11
A
O
2
UI
10
A
O
1
UI
9
B
O
4
B
O
3
B
O
2
B
O
1
RELAYS
0
.
5
A MAX
IM
C
1
IM
C
P
1
UI
8
UI
7
UI
6
UI
5
UI
4
UI
3
UI
2
UI
1
IMC
+
24
VDC
LINKOUT
+
24
VDC
+
24
VDC
OUT
24
VAC
MBUS
OUT
24
VAC
XFMR
24
VAC
SERVICE TOOL
SERVI
C
E
LINK
ACT
IM
C
MBUSLINK
RX
TX
U
C
600
ADDRESS
0
1
2
3
4
5
6
7
8
9
x1
0
1
2
3
4
5
6
7
8
9
x10
0
1
2
3
4
5
6
7
8
9
x100
B
O
4
B
O
3
B
O
2
B
O
1
A
O
6
UI
14
A
O
5
UI
13
A
O
4
UI
12
A
O
3
UI
11
A
O
2
UI
10
A
O
1
UI
9
B
O
4
B
O
3
B
O
2
B
O
1
RELAYS 0.5 A MAX
IM
C
1
IM
C
P
1
UI
8
UI
7
UI
6
UI
5
UI
4
UI
3
UI
2
UI
1
IMC
+
24
VDC
OUT
+
24
VDC
+
24
VDC
OUT
24
VAC
XFMR
24
VAC
SERVI
C
E
IM
C
RX
TX
XM
70
ADDRESS
0
1
2
3
4
5
6
7
8
9
x1
0
1
2
3
4
5
6
7
8
9
x10
B
O
4
B
O
3
B
O
2
B
O
1
IM
C
IM
C
TRANE
XM32
BO1 BO2 BO3 BO4
ADDRESS
x10 x1
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
0
IMC
SERVICE
RX
TX
RELAYS
BO1 BO2
BO3 BO4
NO NC C NO NC C NO NC C NO NC C
1
A B
IMC
+24
VDC
ADDRESS
0
1
2
3
4
5
6
7
8
9
x1
0
1
2
3
4
5
6
7
8
9
x10
4321
UI / AO
IM
C
1
IM
C
IMC
+
24
VD
C
SERVI
C
E
IM
C
RX
TX
XM
30
ADDRESS
0
1
2
3
4
5
6
7
8
9
x1
0
1
2
3
4
5
6
7
8
9
x10
4321
UI / AO
IM
C
1
IM
C
IMC
+
24
VD
C
SERVI
C
E
IM
C
RX
TX
XM
30
TRANE
XM32
BO1 BO2 BO3 BO4
ADDRESS
x10
x1
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
0
IMC
SERVICE
RX
TX
RELAYS
BO1 BO2
BO3 BO4
NO NC C NO NC C NO NC C NO NC C
1
A B
IMC
+24
VDC
ADDRESS
0
1
2
3
4
5
6
7
8
9
x1
0
1
2
3
4
5
6
7
8
9
x10
4321
UI / AO
IM
C
1
IM
C
IMC
+
24
VD
C
SERVI
C
E
IM
C
RX
TX
XM
30
ADDRESS
0
1
2
3
4
5
6
7
8
9
x1
0
1
2
3
4
5
6
7
8
9
x10
4321
UI / AO
IM
C
1
IM
C
IMC
+
24
VD
C
SERVI
C
E
IM
C
RX
TX
XM
30
Red wire
removed
24 Vac
XM70/XM90
XM30
XM32
UC600 controller
XM32 XM30
24 Vac
Important: Do not connect 24 Vdc power between
the XM30 expansion module and the XM70/XM90
Figure 10, p. 18 illustrates an application with two XM70/90 expansion modules. When
connecting multiple XM70/90 modules, the +24 Vdc must be removed between each UC400/600
and each XM70/90.
VAC input power is provided by the transformer (for UC600 and each XM70/90 module)
Maximum of two expansion modules can be powered by the XM70/90 through the IMC cable.
The IMC cable between the two XM70/90 modules must have the 24 Vdc wire removed.
As an alternative, do not install the +24 Vdc terminals between devices.
The XM70/90 can power up to two XM30 or XM32 expansion modules.