3. Press down on the reservoir cap to hold it in position and install the reservoir cap bolt using a
TX6 key and medium strength thread locker (e.g. Loctite 243). Torque it down to 1Nm.
Note: To check whether the assembly of the membrane was successful, you can apply
negative and positive pressure (alternating) to the syringe during bleeding after the service. If
the seal is damaged, drawing a vacuum at the brake pump with the bleeding syringe will result
in air intake, or positive pressure can result in oil exit. In this case, take off the membrane
again and check it for damages optically, then give the assembly another try.