17
USERS GUIDE
17
PROTECTIVE SHUTOFF AND RESTART CONDITIONS
SHUTOFF RESTART
OTHER RESTART
CONDITIONS
Over Voltage Any cell voltage > 3.74V 48V Battery Voltage > 59.8V All cell voltages < 3.64V 48V Battery Voltage < 58.2V
Load attached and
discharging
Low Voltage Any cell voltage < 2.53V 48V Battery Voltage < 40.5V All cell voltages > 2.63V 48V Battery Voltage > 42.1V
Charger attached and
charging
Short Circuit
Current
800A instantaneously No automatic restart
Wait 2 minutes
then press ON/OFF
Power Switch on side
of the battery.
Over Temperature
Discharge
140°F (60°C) 131°F (55°C)
Over Temperature
Charge
131°F (55°C) 12F (5C)
Under Temperature
Discharge
-F (-20°C) 14°F (-10°C)
Under Temperature
Charge
32°F (0°C) 41°F (5°C)
Automatic Sleep
No use for 4 hours or
1 hour if the battery state of charge is lower than 25%
No automatic restart
Use the ON/OFF Power
Switch on the side of the
battery or the dashboard
push button accessory
to manually wake up the
battery.
AS NOTED IN SECTION 2: “SAFETY,” THE SYSTEM INSTALLER/
USER ASSUMES ALL RESPONSIBILITY AND LIABILITY FOR ANY
DAMAGES THAT MAY OCCUR DUE TO SUDDEN LOSS OF POWER.
10.3 PROTECTION LIMITS: AUTOMATIC DISCONNECTION
As outlined in the following table, the Trojan OnePack Lithium-Ion battery will automatically shut down under excessive
use conditions in order to prevent damage to the battery and connected equipment. This will generally result in total loss
of power to equipment. Systems must be implemented, and precautions must be taken to ensure that sudden loss of
power does not result in hazardous system behavior.