B - 2 opera ting instr uctions - clima te da t a logger B l 30 EN
m Make sure that the data logger is always used/
stored in an upright position. This also applies
after measurements taken at low temperatures
or in highly humid environments. The intention
is to avoid any condensation that forms collec-
ting in the appliance; instead, it can escape
from the lower part of the appliance. Wait until
any moisture which may have formed inside
the appliance due to physical processes has
completely evaporated before the collected
data are read out for evaluation. In order to
preserve the batteries, the data logger can also
be directly connected to the PC via USB. When
connected in this manner it draws its power
directly from the PC.
3. Special features
1. Memory space for 32,700 measured values
2. Large, easily readable LCD
3. Freely selectable measurement cycle from 1 sec to 24 hrs
4. USB interface for data transmission to the PC
5. Alarm when exceeding/falling below user-defined li-
mit values
6. Including analysis software for the purpose of graphi-
cally displaying the measurement data.
Spezifikationen
Humidity Measurement range 0 to 100%
Accuracy
(0 - 20 and 80 - 100%)
± 5,0%
Accuracy (20 - 40 and
60-80%)
± 3,5%
Accuracy (40 - 60%) ± 3,0 %
TRO-TR-BA-BL30-HS-002-INT - Kopie.indd 2 08.09.2014 10:19:11

Other manuals for Trotec BL30

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Trotec BL30 and is the answer not in the manual?

Trotec BL30 Specifications

General IconGeneral
Resolution temperature0.1 °C
Resolution humidity0.1% RH
InterfaceUSB
Protection classIP20
Humidity measuring range0% to 100% RH
Accuracy temperature±0.5 °C (at 25 °C)
Memory capacity32, 000 measurements
Measuring rateAdjustable from 1 second to 24 hours