11 EN
Operating manual – local air conditioner PAC 2000 SH
Setting the timer
The timer has two modes of operation:
• automatic switch-on upon expiry of a preset number of
hours
• automatic switch-off upon expiry of a preset number of
hours
The timer can be programmed in increments of 1hour (1h to
24h).
The function can be set in all operating modes. It can be
activated both during operation and in standby mode.
Note
Do not leave the operating device unattended in a
freely accessible room with an activated timer.
Automatic switch-on
ü The device is switched off.
1. Press the timer button(16) to activate the timer.
ð The timer LED(17) flashes.
2. Repeatedly press the plus or minus buttons(14, 22) to
choose the desired number of hours until automatic
switch-on.
3. Wait for 3seconds to confirm the setting.
ð The number of hours until automatic switch-on will be
indicated on the segment display(15) for approx. 3s.
ð The timer LED(17) is illuminated.
ð Then the segment display(15) switches back off.
ð After the predefined time, the device switches itself on.
4. In order to delete the setting, select 00 hours using the
plus/ minus buttons(14, 22).
ð The timer LED(17) goes out.
Notes regarding automatic switch-on:
• If the device is disconnected from the power supply, all
settings for automatic switch-on are deleted.
• Manually switching the device on disables the automatic
switch-on function.
• If you select 0hours, the timer will be off.
Automatic switch-off
ü The device is switched on.
1. Press the timer button(16) to activate the timer.
ð The timer LED(17) flashes.
2. Repeatedly press the plus or minus buttons(14, 22) to
choose the desired number of hours until automatic
switch-off.
3. Wait for 3seconds to confirm the setting.
ð The number of hours until automatic switch-off will be
indicated on the segment display(15) for approx. 3s.
ð The timer LED(17) is illuminated.
ð Then the segment display(15) changes back to the
current room temperature.
ð After the predefined time, the device switches itself off.
4. In order to delete the setting, select 00 hours using the
plus/ minus buttons(14, 22).
ð The timer LED(17) goes out.
Night mode
Night mode can be activated in cooling and heating mode.
Night mode comes with the following settings:
• In cooling mode the preset temperature is increased by
1°C after one hour.
After 2hours the preset temperature will again be
increased by 1°C. Then the temperature is kept constant
for 6hours.
Subsequently, the device will be switched off. The device
is in standby mode and can be switched back on via
control panel or remote control.
• In heating mode the preset temperature is reduced by 1°C
after one hour.
After 2hours the preset temperature will again be
decreased by 1°C. Then the temperature is kept constant
for 6hours.
Subsequently, the device will be switched off. The device
is in standby mode and can be switched back on via
control panel or remote control.
To activate night mode, please proceed as follows:
1. Select cooling or heating mode.
2. Press the night mode button(21).
ð Both the LED for the selected operating mode(23) and
the night mode LED(20) will be illuminated.
3. In order to switch off night mode, press the night mode
button(21) once again.
ð The night mode LED(20) goes out.
ð The fan speed returns to its previous setting.
Changing the unit °C / °F
The temperature in the segment display(15) can be indicated in
°C or °F.
Please proceed as follows to change the temperature unit:
1. Simultaneously press and hold the plus(14) and
minus(22) buttons for 3s.
ð The displayed temperature is converted to the other unit.