5
SOFTWAVE INSTALLATION
z Introduction
E-Eyes is a unique uninterruptible power supply (UPS) software that offers you unprecedented
convenience for the control of any UPS.
Benefits
Early Warning System.
E-Eyes can send warning messages via e-mail or over the LAN. Thus providing an early warning
system for power failures, system shutdown and a variety of other scenarios. It guarantees a faster
response time, even when you are not in the office.
Saves files before shutdown occurs.
No more lost work due to unexpected system shutdown. When power failure occurs, E-Eyes saves
all open files before gracefully shutting down the system.
Cost Savings.
E-Eyes' shutdown and startup scheduling function reduces the amount of power wasted, and
therefore results in savings on electricity bills. In addition, E-Eyes also allows for remote control
over a TCP/IP network without the need for an expensive SNMP card.
Easy System Monitoring and Tracking.
Users are able to customize various E-Eyes controls such as warning method and alarm messages.
z Features
UPS monitoring utility
Scheduled system shutdown
Graphic display of UPS status
Warning notification via e-mail
and pager
Customized controls
User-definable warnings
Multi-language versions
Easy-to-use user interface
UPS TROUBLESHOOTING
Please check the following solutions, if you have any problem on the UPS.
z Make sure the UPS plug is plugged in the outlet correctly.
z Make sure the AC power is in the range of the rated.
z Check the fuse in the rear panel is molten down.
z Make sure the load capacity is within the rated range.
When you call for service, please provide those information’s:
UPS model / Serial number / Breakdown Date / Details about the Status of the UPS.
4
SPECIFICATIONS
Model 600VA ~ 1000VA
Input Volts Range (on line) 110V(80V~140V) / 220V(160V~280V)
Input Frequency
50 OR 60 ± 3HZ
(AVR) Output Volts Range
110V OUT: 110V±10% / 220V OUT: 220V±10%
Output Volts On Battery
110VAC±10% / 220VAC±10%
Output Frequency On
Battery
50 OR 60 ± 1HZ
Battery Run Time 10~30 MIN
Typical Battery Charge Rated 4hrs to 90% of full capacity
Battery Protection Auto self-test and Discharge protection
Self Test Self test each time switched on
Transfer Time 2~4ms
Outlets USA*2 or IEC *2
Audible Alarm
Battery back-up: Slow beeping (10 Seconds), Battery Low or Overload: Rapid
beeping (1second)
Indicators Green LED On-Line, Back up slash, Red LED Overload: Battery Fault
Interface RS-232
Environment
Ambient Operating: 0-40, 0-95% Humidity, Non-condensing Storage: 15~45
Audible Noise <40DBA (1-Meter from surface)
Dc Start Yes
Surge Energy Rating 240 Joules
Overload Back-up mode 100% shut down, In AC mode 110% alarms (No shut down)
Electrical Protection Automatic cut off on short circuit and input circuit fuse
Modem/Network Protection Rj45(8Wire)One in , One out option for modem or network
Conformance Applicable
Software (Support) Option
Dimensions (mm) L x W x H 270 x 100 x 190