2
Contents
Symbols used ........................................................................ 2
Technical data ..................................................................... 2
Installation instructions
Scope of delivery ................................................................ 3
Accessories for installation (optional) .............................. 3
Intended use ....................................................................... 4
Installation dimensions (in mm) ............................................ 4
Clearance around the air conditioning system ...................... 4
Air inlets / outlets ................................................................... 4
Condensation traps ............................................................... 4
Selecting a location ........................................................... 5
Cut-out installation 400 x 400 .......................................... 5
Installation with new cut-out ........................................... 5
Preparation for power cable connection and control
panelcable ............................................................................ 6
Securing the appliance .......................................................... 6
Use of roof thickness adapters .............................................. 7
Insert the filter into the air distributor ................................... 7
Insert the panels into the air distributor small ....................... 8
230 V electrical connection
............................................... 8
Function check / remote control mounting ........................... 8
Aventa compact plus AU
Symbols used
The device must only be installed and repaired by an
expert.
Symbol indicates a possible hazard.
Note containing information and tips.
Technical data
Determined on the basis of EN 14511 or Truma test conditions
Power supply
230 V – 240 V
, 50 Hz
Power consumption
Cooling: 4.4 A
Starting current
28 A (150 ms)
Cooling power
2.2 kW (T35 /T35)
Air volume flow
max. 400 m³/h
Usage limits
+16 °C to 40 °C
Maximum angle during operation
8 %
Weight
29.5 kg with installation materials
Dimensions (W x H x D)
External: 560 x 265 x 785 mm
Internal: 523 x 46 x 670 mm (air distributor)
Internal: 496 x 46 x 556 mm (air distributor small)
Refrigerant
R 407C / 0.47 kg
Contains fluorinated greenhouse gases covered by the Kyoto
Protocol. Hermetically sealed.
Global Warming Potential (GWP)
1774
CO2 equivalent
833.8 kg
Subject to technical changes.