12
Control panel / air conditioning system
The following connecting combinations are possible.
1 CP plus
control panel
Combi D 6 (Australia)
and
1 Air conditioning
system
Suitable systems – see
CPplus control panel operating
instructions
Insert the plug of the connecting cable into one of the
connections (68 or 69). Make sure that the plug engages.
Metering pump connection
If an automatic filling unit is used to fill the fuel lines,
make electrical connection to metering pump after filling.
Attach connector (74) of connecting cable to metering pump
and connector (75) to connection (70) of unit. Please ensure
that connectors engage properly.
75
Fig. 34
Wind up excess cable and secure in a suitable location using
cable binders.
Extraction fan connection
Attach connector (11) of extraction fan cable to unit con-
nection (72). Ensure that the plug engages. Wind up excess
cable (9) and secure in a suitable location using cable binders.
Fig. 35 – View – vehicle interior
Initial start-up
During the initial operation of a brand new appliance a slight
amount of fumes and smell may be noticed for a short while.
Filling the fuel lines
The heater normally has to be started up several times to fill
the fuel lines.
Connect unit to control panel to do this. The unit automatically
performs 2 start attempts (initial start and repeat) per switch-
on procedure with a run time of 2 minutes in each case. If no
flame is detected after the repeat start, the unit switches to fault
and has to be switched off and on again at the control panel.
After a total of 15 unsuccessful starting attempts (initial
and repeat start) without forming a flame, the equipment
is blocked. To remove the block, please contact the Dometic
Service Centre (see www.truma.com).
Check fuel lines and connections for leaks after filling the fuel
lines.
Function check
Check all functions of the appliance, as specified in the op-
erating instructions, in particular the water draining function.
There shall be no guarantee claims for damage caused
by frost!
The operating instructions must be handed to the owner of
the vehicle.
Warnings
The installer or vehicle owner must apply the yel low sticker
with the war ning information, which is enclosed with the
appliance, to a place in the vehicle where it is clearly visible
to all users (e.g. on the wardrobe door)! Ask Dometic to send
you stickers, if neces sary.