9
Technical data
LPG flow rate with 2.5 mbar
pressure drop
(20° C / 30 mbar)
GSE: 1.0 kg/h
GS 8: 1.5 kg/h
GS 10: 2.0 kg/h
Inlet connection
GSE: 1/4" left-hand union nut
GS 8: Journal Ø 8 mm
GS 10: Journal Ø 10 mm
Outlet connection
GSE: 1/4" left-hand external
thread
GS 8: Cutting ring screw fitting
with external thread,
Ø 8 mm
GS 10: Cutting ring screw fitting
with external thread,
Ø 10 mm
Max. pressure
150 mbar
Nominal Voltage
12 V DC
Power consumption
40 mA
briefly (for opening) 2 A
Protection system
IP 54
Product Ident. Number
GSE: CE-0085AQ0898
GS 8/GS 10: CE-0085AS0506
Ambiant temperatur
- 30° C to + 60° C
Opening and closing time
< 0,1 s
Fitting Position
any
Dirt filter integrated in gas
entrance.
This product is suitable for
operation and installation in
zone II (e.g. a gas cylinder box)
in potentially explosive areas in
accordance with ATEX directive
94/9/EC.
II 3 G EEx nA II T6 X IP54
II 3 G EEx nA II T6 X IP54
In the event of a defect or power
failure the gas remote switch
can be unscrewed from the gas
line.
Before taking the equip-
ment back into opera-
tion, the sealing tightness of the
gas system must be tested in
accordance with the pressure-
drop method!