EasyManua.ls Logo

Truma MonoControl - Operating instructions

Truma MonoControl
40 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MonoControlInstallation and connection
22 EN
50020-00990 ∙ 00 ∙ 08/2022

Install the gas pressure regulator in a suitable place�

Install the gas filter if necessary (see the instructions for the gas
filter)�

Screw the gas pipe onto the gas pressure regulator on the outlet
side using the 8mm or 10mm(H�9) cutting ring screw connec-
tion�

Screw the high-pressure hose onto the gas pressure regulator or
gas filter using the M20x1�5 (G�13) male thread on the inlet side�
2
1
Fig� 3
1 Connection for gas pipe
2 Connection for high-pressure hose or gas filter
4.5 Final steps

Check all the unions in the high-pressure section with a leak-fin-
der spray in accordance with EN14291 to ensure they are tight
(also see the operating instructions)�

After installation, have the entire gas system checked for leaks by
an expert in liquid gas (also see the operating instructions)�

After installation, have the entire gas system checked for leaks
and for proper installation and function by an expert in liquid gas�

If there is a gas testing certificate, this must be supplemented
or changed accordingly� This test does not replace the regularly
scheduled gas check�