7
E08
Output short circuit
The signaling of the code E08
interested output is shown as Uxx
where xx is the number of the
output.
Turn off the
device and then turn it back
on, after having verified the plant of the
solenoid valves.
E11 Maintenance deadline reached Carry out maintenance.
E14
Indicates that a valve in short
circuit has been excluded from the
cycle.
The signaling of the code E14
interested output, is shown as Uxx
where xx is the number of the
output.
An output is considered a short
circuit if not responding for 3
following activations.
An activation without error resets
the counting.
Turn off the device and then turn it back
on, after having verified the plant of the
solenoid valves.
E20 Internal clock error.
Replace buffer battery (CR1632 3V
130mAh) and set current time and date