3.5 Unpacking description
In the outdoor unpacking process, it is prohibited to operate in rainy conditions;
If there is wind in the field, special attention shall be paid. Particularly in the event of heavy
wind, it is recommended not to handle the module, and it is necessary to properly secure the
unpacked Modules;
The working surface shall be such that the packing box can be placed in a stable, level
position, avoiding being overturned;
During the unpacking, it is necessary to wear protective gloves, and avoid scratching the
hands and leaving the fingerprints on the glass;
In the case of operation not according to the requirements or in the case of an unskillful
operation, it will result in the fall-off of the protective corner in small amounts, which will
be normal. The effect of the protective corner is to reduce damage due to external force
during transport, and the fall-off of the protective corner will not influence the reliability of
the Modules;
Before the unpacking, it is necessary to carefully check the product information on the
carton box, and carefully read the unpacking instruction;
Every module shall be carried by two people. When carrying the module by two people, it
is prohibited to pull the junction box.
04 MECHANICAL INSIALLATION
4.1 Location Selection
Select suitable places to install Modules.
Install Modules at the places with sufficient sunlight and without shade at any time. If a
module is shaded or even partially shaded, it will result in lower power output. A
permanent or regular shade will cause module damage, which will result in the invalidity
of product’s limited warranty.
Do not store, install or use Modules at the places where combustible gas is easily generated
or gathering.
Modules can be installed on land 50 to 500m away from the coastline. However, the
connectors must be well protected or a dust-proof plug must be added when installing
Modules within this distance. Connect the dust-proof plug immediately after removing it,
and take other anti-rust measures to prevent the parts from rusting.
Modules in the same string should be installed at the same angle. Modules installed in
different angles will receive different irradiation, which will cause current different. As a
result, it will decrease the operation efficiency of the system.