USER GUIDE
Control Operation - Service 3
u-line.com
SAFETY INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS MAINTENANCE SERVICE
Service Mode Guide
Number Service Mode Menu Item To Navigate/Access
1 View thermistor #1 cabinet temp no offsets Use up/down to access and light bulb key to view
2 View thermistor #2 evaporator no offsets Use up/down to access and light bulb key to view
3 View thermistor #3 ambient no offsets Does not apply to this model
4 View thermistor #4 ice maker no offsets Does not apply to this model
5 Adjust thermistor #1 offset Call tech line for assistance 800 779 2547
6 Adjust thermistor #2 offset Call tech line for assistance 800 779 2547
7 Adjust thermistor #3 offset Does not apply to this model
8 Adjust thermistor #4 offset Does not apply to this model
9 View thermistor #2 set point no offsets Use up/down to access and light bulb key to view
10 View thermistor #3 set point no offsets Does not apply to this model
11 View thermistor #4 set point no offsets Does not apply to this model
12 Adjust defrost interval 3 to 12 hours Up/down to select, light icon to enter and save change
13 Adjust defrost duration 0 to 99 minutes Up/down to select, light icon to enter and save change
14 Display error log Use up/down to access and light bulb key to view
15 Clear error log Use up/down to access and light bulb key to clear
16 View thermistor #1 differential Do not make any changes to this
17 Fan on delay (start of cooling cycle) Up/down to select, light icon to enter and save change
18 Fan off delay (after cooling cycle stops) Up/down to select, light icon to enter and save change
19 Component testing (see service mode) Use up/down to access, light bulb icon to toggle on/off
20 Display programmed model number Use up/down to access, light bulb icon to display
21 Light all LED segments of display (test) Use up/down to access and light bulb key to view
22 Display defrost cycles in last 24 hours Use up/down to access and light bulb key to view
23 Displays last/current compressor run time Use up/down to access and light bulb key to view
24 Activate harvest cycle Does not apply to this model
25 Restore factory defaults Use up/down to access and light bulb key to restore
26 Display control board software version Use up/down to access and light bulb key to view
27 Display user interface software version Use up/down to access and light bulb key to view
28 Monitor unit function through laptop/PC Call tech line for assistance 800 779 2547
0 To exit service mode Use up/down to scroll and light bulb icon to exit