Thermistors
Thermistors are used for various temperature readings.
Thermistors provide reliable temperature readings using a
resistance which varies based on surrounding
temperatures. If a faulty thermistor is suspected it may
be tested using an accurate ohmmeter.
THERMISTOR FAILURE
Zone Thermistors
If the zone thermistor in the unit fails the unit will continue
to cool in a back up mode to preserve the integrity of the
contents. The unit will cycle on for ten minutes, then shut
down for forty five minutes. The process will repeat until
the problem is corrected. All other functions of the unit
will continue to operate normally.
Evaporator Thermistors
If an evaporator thermistor fails the unit will rely on a
preset defrost timer during defrost cycles. The unit will
otherwise operate normally. The error will be displayed in
the service mode “Error Log.”
This unit has two thermistors. Thermistor one is located
along the right hand side wall inside of the unit and is used
to maintain temperature within the unit.
Thermistor two is located on the back of the evaporator
and is used for defrost purposes.
Thermistor connections must be kept clean. A thermistor
connection that has become corroded can cause
resistance values from the thermistor to change as they
pass through a dirty connection to the board.
It is for that reason that we apply die electric grease to all
of our thermistor connections. Die electric grease will help
to keep thermistor connections clean and dry.
If you change a thermistor in the unit please re-apply die
electric grease to the connection. If you encounter a dirty
thermistor connection, you should replace the thermistor
and the thermistor harness.
Thermistor Resistance Data
Temp (F) Temp (C)
Nominal Resistance
(OHMS)*
-40 -40 169157
-31 -35 121795
-22 -30 88766
-13 -25 65333
-4 -20 48614
5 -15 36503
14 -10 27681
23 -5 21166
32 0 16330
41 5 12696
50 10 9951
59 15 7855
68 20 6246
77 25 5000
86 30 4029
95 35 3266
104 40 2665
113 45 2186
122 50 1803
131 55 1495
140 60 1247
149 65 1044
158 70 879
167 75 743
176 80 631
* (=/-5%)