EasyManua.ls Logo

U-Line H-10646 - Maintenance

U-Line H-10646
18 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PAGE 4 OF 18 1222 IH-10646
OPERATION CONTINUED
MAINTENANCE
W
ARNING! A falling lift table can cause severe
personal injury or death. Never go under the
platform until the load is removed and the
scissors mechanism is secured in the raised
position with the safety bars. The safety
bars are designed for use only when the lift
is unloaded. Never place any load on the
platform with the safety bars engaged. Severe
personal injury, death and property damage
could result.
W
ARNING! Do not put foot or hand in scissor lift
mechanism.
WARNING! The table uses a power supply of 115
Volts AC. This voltage can cause serious injury
or death. Do not work with electrical parts
unless you are a qualified electrician.
ADDING OIL
If the platform won't raise to the rated height, hydraulic
fluid may need to be added. Hydraulic fluid must be
ISO VG32 or equivalent with a viscosity of 32cSt at 104°F.
Mixing of different fluids is prohibited.
NOTE: When platform is at minimum height,
the hydraulic oil level is about two-thirds of the
height of oil tank.
NOTE: Waste oil must be disposed of in
an environmentally friendly way and in
accordance with regulatory authorities.
LUBRICATION
Periodically lubricate all grease fittings according to
the required maintenance schedule using multipurpose
lubricating grease ZG2# or 3#.
WARNING! Remove load and engage
safety bars before performing inspection
or maintenance work. (See Figure 8)
CAUTION! Safety bar automatically stops table
movement when in operation.
MAINTENANCE SCHEDULE
DAILY:
Before use, visually inspect the table for worn,
damaged or broken components. If any of these
conditions exist, do not use the table and contact a
qualified service person.
Raise the platform and visually inspect the hydraulic
components (i.e. pump, hoses, fitting and cylinders)
for oil leakage.
If oil leakage exists, do not use the table and
contact a qualified service person.
Raise the table and disengage the maintenance
bars by returning them to their stored position.
Figure 8
Safety Bar

Related product manuals