PAGE 7 OF 33 0819 IH-5819
OPERATION CONTINUED
CLEAR CHECK COUNT
1. Press the MODE key
Mode
until C PCS is shown on
the display.
2. Press the HI key
MR
HI
. Current high limit will be shown
on the display.
3. Enter 0 using the numeric keypad.
4. Press the ZERO key
Zero
.
5. Press the LO key
MC
LO
. Current low limit will be shown
on the display.
6. Enter 0 using the numeric keypad.
7. Press the ZERO key
Zero
.
ACCUMULATION
Use this mode to measure the cumulative weight or
counting values of a sequence of items. The maximum
number of samples is 99 entries or the scale capacity.
MANUAL ACCUMULATION
1. Follow steps above to weigh or count items on the
platform.
2. Once the stable indicator is shown on the display,
press the M+ key
M
+
. AC 1 will be shown on the
display and the total value will be displayed for two
seconds. Weighing or counting value will be stored
into memory. If a printer is connected, the data will
print. Once data is stored, the M+ indicator will be lit
up on the lower right-hand corner of the display.
AC 1
3. Remove items from the platform. Display will return to
zero or a negative value.
4. Add additional items to the platform.
5. Once the stable indicator is shown on the display,
press the M+ key
M
+
. New data will be added to
memory. Continue until all data is added.
6. If counting in accumulation mode:
As the pieces are added, the total quantity will be
displayed.
Press the U/N/G key
U/N/G
to display the unit weight,
gross weight and total quantity.
RECALL DATA
1. Press the MODE key
Mode
until ACCU is shown on
the display.
ACCU
NOTE:
If unit weight was preset or added to
memory, scale will automatically enter counting
mode when accumulation mode is selected.
2. Press the MR key
MR
HI
to display the total weighed
value of items stored to memory. Number of
accumulated values and total weighed value will
be displayed for three seconds.
3. Press and hold the MR key
MR
HI
to display the total
counted value of items stored to memory. Number of
accumulated values and total counted value will be
displayed for three seconds
CLEAR DATA
1. Press the MODE key
Mode
until ACCU shows on display.
ACCU
2. To clear weighing and counting data stored to memory,
press the MC key
MC
LO
. CLEAR
will show on display.
AUTOMATIC ACCUMULATION
Use this mode to automatically add weighing and
counting values to the scale memory and to print values
if a printer is connected.
NOTE: Automatic accumulation must be
enabled. See Enable Automatic Accumulation
section on page 9.
When in the automatic accumulation mode, the auto
indicator will be shown in the upper righthand corner of
the display.
1. Place items to be weighed or counted on the platform.
2. Once the stable indicator is shown on the display,
the scale will make a beeping sound.
3. Remove items from the platform. Display will show
AC 1 followed by the weighing or counting value.
Weighing or counting value will be stored into
memory. Once data is stored, the M+ indicator will
be lit up on the lower right hand corner of the display.
AC 1
4. The scale will return to the weighing mode. Display
will return to zero or a negative value.