PAGE 10 OF 36 0319 IH-5836
SETUP MENU CONTINUED
AUTO POWER-OFF
When the auto power-off time is enabled, the scale will
automatically turn off when there has been no load on
the platform and the scale is stable at zero position for a
specified period of time (in minutes). At startup, the auto
power-off is disabled. Enter this menu to turn the auto
power-off feature on or off.
1. Press and hold the ZERO key
for three seconds.
SET bF will be shown on the display.
2. Press the TARE key
until SET oF is shown on the
display.
3. Press the ZERO key
to enter the auto power-off
menu.
4. Press the TARE key
until the desired setting is
shown on the display.
oFF – Auto power-off is off.
oF 5 – Auto power-off at 5 minutes.
oF 15 – Auto power-off at 15 minutes.
5. Press the ZERO key to select the new setting.
6. Press
the UNIT key to exit the sub menu.
HIGH/LOW LIMIT BEEPING SOUND
At startup, the beeping sounds are set to beep when
weights are inside the limits. Enter this menu to change
the beeping sound setting.
1. Press the UNIT key
and the PCS/SET key at
the same time until SEt H is shown on the display.
2. Press the TARE key
until bEEP is shown on the
display.
3. Press the ZERO key
to enter the submenu.
4. Press the TARE key
until desired setting is shown
on the display.
nonE – No beeping sounds.
o – Beeping sounds between the limits.
nG – Beeping sounds outside of the limits.
5. Press the ZERO key
to select the new setting.
6. Press the UNIT key
to exit to the weighing mode.
ENABLE DYNAMIC WEIGHING
At startup, the dynamic weighing mode is enabled. Enter
this menu to turn the dynamic weighing mode on or off.
1. Turn on the scale and press the PCS key during the
self-test. Pn will be shown on the display.
2. Press the
G/N key
, then the
UNIT key
and
then the
TARE key . Po CHF will be shown on the
display.
3. Press the TARE key until P3 oth is shown on the
display.
4. Press the ZERO key
to enter the menu. anm will
be shown on the display.
5. Press the ZERO key
to enter the sub menu.
6. Press the TARE key
until the desired setting is
shown on the display.
on – Dynamic weighing is on.
oFF – Dynamic weighing is off.
7. Press the ZERO key
to select the new setting.
8. Press the UNIT key
twice to exit the menu.
ENABLE ACCUMULATION, AUTO
ACCUMULATION AND RS-232
At startup, the accumulation mode is enabled. Enter this
menu to turn the accumulation and auto accumulation
modes on or off and to set the RS-232 communication.
1. Turn on the scale and press the PCS key
during
the self-test. Pn will be shown on the display.
2. Press the G/N key
, then the UNIT key and
then the TARE key
. Po CHF will be shown on the
display.
3. Press the TARE key
until P1 com is shown on the
display.
4. Press the ZERO key
to enter the menu. Mode
will be shown on the display.