EasyManua.ls Logo

U-Line UHNB315 - Service and Troubleshooting; Quick Guide and Service Modes

U-Line UHNB315
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
USER GUIDE
u-line.com
Quick Guide
Quick Guide
0. Exit
1. Thermistor1temperaturenotincludingosets.
2. Thermistor2temperaturenotincludingosets.
3. Thermistor3temperaturenotincludingosets.
4. Thermistor4temperaturenotincludingosets.
5. Thermistor1oset.(+/-10)
6. Thermistor2oset.(+/-10)
7. Thermistor3oset.(+/-10)
8. Thermistor4oset.(+/-10)
9. Thermistor 2 set point
10. Thermistor 3 set point.
11. Thermistor 4 set point.
12. DefrostInterval(0to99hr)
13. Defrostduration(0to99min)
14. ErrorLog(SeeAppxD)
15. Clearerrorlog(holdlightkeyuntilcleared)
16. Thermistor1dierential(+5)
17. Thermistor3dierential(+5)
18. Evaporatorfanondelay(0to99sec)
19. Evaporatorfanodelay(0to99sec)
20. Individual component toggle
- Option#0–Exit
- Option#1–Relay1
- Option#2–Relay2
- Option#3–Relay3
- Option#4–Relay4
- Option#5–Relay5
- Option#6–Relay6
- Option#7–DCOutput1
- Option#8–DCOutput2
- Option#9–DCOutput3
- Option#10–DCOutput4
- Option#11–DCOutput5
- Option#12–Serialoutput(Compressor)
21. Model number
22. LightAllSegments
23. ActivateDefrost/Harvest-pressandholdfor3
secondstoactivatedefrost/harvest
24. Defaults-pressandholdfor3secondsto
restoreallvaluestofactorydefaults.
25. MainSoftware(Displayonly)
26. LiveLogPeriod(frequencythatdataisoutput
todiagnosticsport)
27. Factorytestmode(0=O,1=On)
28. CompressorRPM
29. Freezetimeadjust(Model54only)
30. Harvesttimeadjust(Model54only)
31. Lowtempalarmlimit(Model55only)
32. Hightempalarmlimit(Model55only)
ERRORS
*Allerrorsareloggedinmemory.
*Onlydoorerrorisdisplayedonthedisplayandhasan
audible signal.
*For68118models,pumperrorisdisplayedviaalert
lightwithnoaudiblealert.
E1: Thermistor 1 open.
E2: Thermistor 2 open.
E3: Thermistor 3 open.
E4: Thermistor 4 open.
E5: Thermistor 1 shorted.
E6: Thermistor 2 shorted.
E7: Thermistor 3 shorted.
E8: Thermistor 4 shorted.
E9: Door 1 open error.
E10:(displayedas10):Door2open
E11:(displayedas11):Waterlevel(trayorreservoir)
high.
E12:(displayedas12):Waterlevellow.
E13:Augererror
P1: Pump circuit open
SERVICE MENU
26

Related product manuals