UAV-1004045-001 AV-30-C ICA 14 Revision A
7.8 Visual Inspection Procedure
Perform a visual inspection as detailed in this section.
Inspect the unit and verify it is securely mounted.
Inspect the unit fasteners and verify they are properly torqued (6
+/- 1 Inch LBS) and show no wear or damage.
Inspect unit support structure and verify it is in good condition
and its integrity is not compromised.
Inspect the condition of the wiring.
Verify that all wiring and cables are securely fastened.
Verify that the harness shows no signs of cracking, chafing,
abrasion, melting, or any other form of damage.
Inspect unit connector and ground strap for corrosion, evidence
of moisture, or other defects.
Inspect pneumatic connections and repair or replace those parts
that are defective (e.g., broken “B” nuts, cracked flare sleeves,
deteriorated flexible tubing, bad valves). Purge the system, if
necessary, to remove foreign matter that may have accumulated
in the tubing.
Inspect display screen to ensure it is clean and free of debris. If
cleaning is required, utilize a soft cloth and glass cleaner. Do not
clean with alcohol-based solvents.
Caution—Be sure to remove all pitot pressure and static air
connections to every instrument before purging the system
tubing.