WARNING!
Before using this system, it is imperative to have received the appropriate dive training and obtained a diving
certificate issued by an approved organisation. WATERPROOF does not accept any responsibility in the event
of an incident caused due to lack of training, misuse or unsuitable usage.
USER MANUAL
These instructions cover the Waterproof Dry Glove System ULTIMA Twist for dry diving suits according to
EN14225-2.
DESIGNATED USE
This Ultima Twist Dry Glove System is approved for Waterproof drysuits with FlexLock system, SI TECH QCS
Oval System or Latex wrist seals. In combination with insulating dry glove, the Ultima system will provide your
hands with thermal protection in and under water. Ask Waterproof for suitable dry gloves: info@waterproof.eu.
STORAGE
Store away from sources of UV radiation (mainly sunlight). Optimal storage conditions: 65% humidity, 21° C,
protected from light and without mechanical, chemical and physical influences. Inspect regularly (every six
months).
OPERATING TEMPERATURE RANGE -2° C to 30° C
CAUTION!
Prolonged exposure to heat or UV rays can cause plastic decomposition.
CARE AND MAINTENANCE
Rinse and clean the dry glove system with fresh cold water after each dive. Pay extra attention to the large
sealing o-ring inside the glove ring. Never drop your ring system on any hard surfaces, this may cause the parts
to break. Be extra careful of the sealing parts on the suit ring and glove ring. If it becomes hard to don and doff,
add some Silicone grease to the sealing o-ring.
Replace all o-rings after 30 months or when signs of cracks or damage are visible.
For disinfection please email: info@waterproof.eu
PRE DIVE CHECK
Always dive with wrist seals installed.
Make sure the sealing o-ring is clean and intact before mounting the glove ring.
Check before every dive everything is mounted correctly and gloves and seals are intact.
Check the equalization tube is installed to equalize the pressure between suit and glove.
Make sure you visually check the glove ring is mounted correctly and close to the suit ring on all sides before
diving.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ultima TWIST and is the answer not in the manual?

Ultima TWIST Specifications

General IconGeneral
BrandUltima
ModelTWIST
CategoryDiving Instrument
LanguageEnglish