To Clean/ Change Contaminated Water
Remove large water bucket and filter assembly from under the machine.
Sprinkle into water one bottle of “UNI-COAG”. Stir in the powder using the mixing paddle provided
for at least 2 minutes. It is very important that the powder is thoroughly stirred into the contaminated
water for coagulation to take place.
Leave to stand and within 5 minutes the water will clear.
When the water is clear place the Filter Assembly over a foul water drain and pour away the water
collecting the paint residue in the Filter Cloth Bag. (providing permission from the Local Water
Authority has been granted. Otherwise the water can be reused or disposed of in accordance with
the local regulations).
Remove the Filter Cloth Bag and place in paint oven to assist the drying, or leave to dry outside. The
residue reduces by approximately two thirds and reverts to a powder from which can be disposed of
with your solid waste.
1
2
3
4
5
MAINTENANCE CHECK:
Grid Filter:
It is recommended that the Green Grid Filter inside the tank under the Work Screen is
changed once a month.
Suction Filter:
It is recommended that the Suction Filter be cleared thoroughly every time the cleaning
fluid is replaced.
Please note:
If the Suction Filter is damaged or removed, the Pump Warranty is void.
Lubrication:
The air valve is lubricated at the factory and designed to operate without additional
lubrication. If added lubrication is desired, every 500 hours of operation (or monthly)
Remove the hose from the pump air inlet and add two drops of machine oil to the air
inlet.
The Unic range of Gun Cleaning Machines are Category 2 equipment that is suitable for
Apparatus Groups (Gas groups) IIA, IIB and IIC, with a temperature class of T6.