13
Instructions for the installer
PACKAGING DIMENSIONS A B C
ALKON 24/35 B 60 675 989 575
C
A
B
3.3 - PACKAGING
The ALKON range of boilers are supplied fully assembled in a
strong cardboard box.
After having unpacked the boiler check that it
is intact and undamaged.
Keep the packaging material (cardboard box,
plastic bags, polyester protection etc.) out of
the reach of children as they can be dange-
rous.
UNICAL refuses all liability for injury to persons,
animals or damage to property deriving from
not having respected the above mentioned re-
commendations.
In the packaging, in addition to the boiler, you can also find
the following contents:
- Service logbook
- User’s instruction guide
- This installation and servicing manual
- Warranty
- Nr. 2 spare parts request coupons
- Nr. 2 wall plugs for fixing the boiler to the wall
- Pipe kit
- Wall mounting template
- Condensate drain siphon
3.2 - STANDARD CODES FOR INSTALLA-
TION
The appliance must be installed in compliance to the instruc-
tions contained in this manual.
The installation must be carried out by a competent qualified
engineer, whom will assume the responsibility of complying
to all the local and/or national regulations published in the
official publications, as well as all the applicable codes of
practice.
Before installing the appliance please contact the gas supply
company.
The installation must be carried in accordance to the codes of
practice, the regulations and the requirements hereby indica-
ted, which constitute an indicative list, but not a complete one,
as these continue to undergo developments.
National installation regulations:
Gas plants for domestic use fed by network distribution
Standard UNI-CIG 7129
Gas plants for domestic use not fed by network distribution
Standard UNI-CIG 7131
Law dated 5.03.90 n°46
D.P.R. 447/91
D.M. n° 37 del 22/01/2008
Legge del 9.01.91 n°10
D.P.R. 412/93
Other applicable statutory requirements:
Law 1083/71 (ref. Standard UNI for the design, installation
and maintenance).
D.M 1.12.1975
D.M. 174 - 6 Aprile 2004
UNI 11071: Gas fired heating boilers - Specific
requirements for condensing boilers
Moreover, the boiler must be installed in accordance to all the
regulations regarding the boiler room, and comply to the bu-
ilding regulations and the prescriptions regarding central he-
ating plants in force in the country the boiler is installed.
The appliance must be installed, commissioned and serviced
according to the regulations in force. This is also valid for the
hydraulic system, the flue outlet system and the boiler loca-
tion room.