28
Instructions for the installer
L min = 1 m - L max = 7 m
KIT5820C
KIT5730C
(1 m)
00361255
Preliminary operations:
- Insert the supplied pipe Ø 80 in the adapter for coaxial
pipes Ø80/125 (code 00361255)
- Fit the assembly pipe/adapter on the boiler as shown in
figure.
VERTICAL FLUE OUTLET WITH COAXIAL DUCTS Ø80/125 mm - TYPE C 33
The minimum allowed length of the horizontal
coaxial pipes is 1 meter.
The maximum allowed length of the horizontal
coaxial pipes is 7 meters.
For every additional curve the maximum
allowed length must be reduced by 1 meter.
Layout NOT suitable for ALKON 70