Technical parameters for heat pump space heaters
Model
HP_OWER ONE 160RT160RTK
Air-to-water heat pump
Water-to-water heat pump
No
Brine-to-water heat pump
No
Low-temperature heat pump
No
Equipped with a supplementary heater
No
Heat pump combination heater
No
Parameters shall be declared for low-temperature application 35°C
Parameters shall be declared for average climate condition
Item Symbol Value Unit
Item Symbol Value Unit
Nominal Thermal capacity P
nominale
14 kW
Seasonal space heating
energy efficiency
η
s
177 %
Declared capacity for heating for part load at indoor
temperature 20°C and outdoor temperature Tj
Declared coefficient of performace or primary energy ratio for
part load at indoor temperature 20°C and outdoor
temperature Tj
T
j
= -7°C Pdh 12,0 kW
T
j
= -7°C COP
d
2,88
T
j
= +2°C Pdh 7,3 kW
T
j
= +2°C COP
d
4,33
T
j
= +7°C Pdh 5,7 kW
T
j
= +7°C COP
d
5,83
T
j
= +12°C Pdh 6,7 kW
T
j
= +12°C COP
d
8,12
T
j
= bivalent temperature Pdh 12,0 kW
T
j
= temperatura bivalente COP
d
2,88
T
j
= Operation limit
temperature
Pdh 11,7 kW
T
j
= bivalent temperature COP
d
2,60
For air-to-water heat pump:
T
j
= -15°C
(if TOL < -20°C)
Pdh - kW
T
j
= Operation limit
temperature
COP
d
-
Bivalent temperature T
biv
-7 °C
For air-to-water heat pump:
Tj = -15°C ( if TOL ˂ -20°C)
TOL -20 °C
Cycling interval capacity for
heating
P
cych
- kW
For air-to-water heat pumps:
Operation limit temperature
COP
cyc
-
Degradation co-efficient
T
j
= 7°C
Cdh 0,981 -
Cycling interval efficiency WTOL 60 °C
Degradation co-efficient
T
j
= 12°C
Cdh 0,977 -
Power consumption in modes other than active mode
Supplementary heater
Off mode P
off
0,019 kW
Rated heater output P
sup
- kW
Thermostat-off mode P
To
0,019 kW
Type of energy input - Standby mode P
SB
0,019 kW
Crankcase heater mode P
CK
0,030 kW
Other items
Capacity control variabile
For air-to-water heat pumps:
rated air flow rate, outdoors
- 10000 m
3
/h
Sound power level,
indoors/outdoors
L
WA
- / 68 dB(A)
For water- or brine-to-water
heat pumps: rated brine or
water flow rate, outdoor heat
exchanger
- - m
3
/h
Annual energy consumption Q
HE
6210 kWh