Support for up to 64 Receiving Table ( 32 Zone /
8 Channels per Zone ). Receiving Table can be
set to Single Channel on, Multi-channel, Normal
or Priority Scan.
( Users can switch channel knobs to select
dispatch / On Site, Fire Fighting, Team
Communication Channel, Priority or Normal
Scan Mode to listen to both channels on duty )
B3. Multi-functional receiving table is for users to set up the own receiving mode
B3-1. G Series Voice Pager provides 8 Zones by software settings and 8 channels
corresponding to Channel knobs, which means 64 channels for selecting. (Unication can
modify the provided channels to 256 channels)
B3-2. (a) G4 (G5 Series) 's first 4 zones (A~D) 32 channels' receiving mode must be
programmed in PPS (Pre-programming System). It can't be modified through any
methods but PPS.
(b) The zone E's 8 channels can be planned only for Control center's use. It can be
programmed, increased, modified or deleted through OTAP (on the air
programming).
(c) The last 3 zones ( F、G、H ) can be for Scanner mode used and set by users. Users
can assign the frequency scanned by first scan mode to a specific channel for next
use. Users can switch the channel knobs to the channel assigned by the frequency
and start their control. Users can also assign a new frequency to that used channel.
B3-3. Each receiving table can be set (by PPS) as the following receiving mode The detail is as
follows.
5