UNINEX INTERNATIONAL
5780 SMITHWAY STREET COMMERCE, CA 90040
T. 800-864-3288 / 323-890-9246 / F. 323-890-9249
KOOLZONE
MOBILE SPOT COOLER
THANK YOU FOR PURCHASING THE KOOLZONE MOBILE SPOT COOLER.
PLEASE READ THE INSTRUCTIONS BEFORE USING.
AND PLEASE KEEP THESE INSTRUCTIONS FOR REFERENCE.
QUICK USER GUIDE FOR SAC-1800

Other manuals for UNINEX KOOLZONE SAC-1800

Question and Answer IconNeed help?

Do you have a question about the UNINEX KOOLZONE SAC-1800 and is the answer not in the manual?

Summary

Parts Identification and Duct Fitting

Machine Components

Identifies key parts of the Koolzone Mobile Spot Cooler, including cooling duct, particle filter, and water tank.

Cold Air Duct Installation

Provides instructions for fitting the curved and cooling ducts to the unit.

Operational Guidelines

Keep Distance Recommendations

Specifies required clearances for cooling, heating, and air outlets for optimal operation.

Power On and Direction Adjustment

Details how to turn the spot cooler on and adjust the direction of the airflow.

Water Tank Draining

Explains the procedure for accessing and draining the unit's water tank.

Usage Notes

Optimum Operating Conditions

Outlines the ideal temperature range for the cooler and expected ambient temperature reduction.

Overview

The document describes the Koolzone Mobile Spot Cooler (Model SAC-1800), a portable air conditioning unit designed for spot cooling. It is manufactured by Nakatomi Co., Ltd. and exclusively distributed by Uninex International.

Function Description

The Koolzone Mobile Spot Cooler is designed to provide localized cooling. It operates by drawing in ambient air, cooling it, and then expelling the cooled air through a flexible cooling duct. The unit also features a heating outlet, though its primary function is cooling. The device is intended to reduce the ambient temperature in a specific area, making it suitable for various applications where targeted cooling is required.

Important Technical Specifications

  • Model: SAC-1800
  • Optimum Operating Temperature Range: 64°F - 104°F (17.8°C - 40°C)
  • Temperature Reduction: Proper usage of the unit, specifically at the cooling duct, can reduce the ambient temperature by 10°F - 15°F (5.6°C - 8.3°C).
  • Water Tank Capacity: 3 Liters (3L)
  • Power: The unit is powered via a power cord.
  • Ducting: Features a cooling duct and a curved duct for directing airflow.
  • Filtration: Equipped with a particle filter.

Usage Features

Installation: The installation process for the cold air duct involves two main steps:

  1. Curved Duct Installation: The convex part of the bending duct is inserted into the concave part of the bending base. It is then rotated, and a releasing-locking ring is used to fix the bending duct in place.
  2. Cooling Duct Installation: The fringe of the cooling duct is slid into the slot of the curved duct. The cooling duct is then turned clockwise to lock it, ensuring a secure connection before use.

Operation:

  • Turning On/Off: The unit has a simple operation switch with "ON" and "OFF" positions.
  • Direction Adjustment: The cooling duct can be rotated 360 degrees, allowing users to direct the cooled air precisely where needed.

Important Distances for Operation: To ensure optimal performance and safety, specific distances should be maintained from the outlets:

  • Cooling Outlet: Direction above 30cm (approximately 11.8 inches).
  • Air Outlet: Direction above 20cm (approximately 7.9 inches).
  • Heating Outlet: Direction above 40cm (approximately 15.7 inches).

Water Tank: The unit includes a 3-liter water tank. The water tank covering panel can be removed to access the tank. A water variance observing hole allows users to monitor the water level.

Maintenance Features

Particle Filter: The presence of a particle filter suggests that regular cleaning or replacement of the filter will be necessary to maintain air quality and the unit's efficiency.

Water Tank Management: The water tank needs to be drained periodically. The design includes a water tank covering panel and a handle space hole, likely for easier access and removal of the tank for draining or cleaning. A grounding screw is also visible, which is important for electrical safety and maintenance.

The manual emphasizes the importance of reading the instructions before use and keeping them for future reference, indicating that proper usage and maintenance are crucial for the device's longevity and performance.

UNINEX KOOLZONE SAC-1800 Specifications