Computer Continuous Sending Mode (C18=4)
CR LF
{
{
{
S1 S2 S3 Data S4
Symbol Interpretation
S1: weight status, ST=standstill, US=not standstill, OL=overload
S2: weight mode, GS=gross mode, NT=net mode
S3: weight of positive and negative, “+” or “-”
Data: weight value, including decimal point
S4: “kg” or “lb” CR: carriage return
LF: line feed
PC or Remote Display Continuous Sending Mode (C18=5)
<STX> <POL> XXXXX.XX <LB/KG> <GR/NT> <STAT> <CR> <LF>
Polarity:
<SP>=Positive
“-” = Negative
Weight
Data
Gross/Net: GR
= Gross
NT= Net
Line Feed
Start
Transmission
Units:
lb =punt
kg =
kilogram
pcs =
pieces*
Status:
<SP>= Valid
M = Motion
O = Over/
Under
range
Carriage
Return
Print to Adhesive Label Printers (C18=5) & (C18=6)
The following are the printing formats:
Date: 05/01/2017
Time: 11:30:52
Net: 25.6Ib
Tare: 10.3Ib
Gross: 35.9Ib
Prime Label Printer
Date: xx.xx.xx (yy.mm.dd)
Time: xx.xx.xx (hh.mm.ss)
Net: 6.00kg (net weight)
Tare: 2.88kg (tare)
Gross: 8.88kg (gross weight)
Zebra Label Printer