SCUBAPRO S600-S550 SECOND STAGES
2003 SCUBAPRO
Important note
: The following information is not designed to be a complete training guide for servicing the listed SCUBAPRO regulators. All SCUBAPRO
technicians are required to attend an annual service training program to insure safe handling and servicing of SCUBAPRO products. All SCUBAPRO technicians
must be employed by an authorized SCUBAPRO facility.
12
Replace the adjustable orifice o’ring and
lubricate properly. Inspect the air barrel
o’ring and replace if necessary. Lubricate
properly.
Push the adjustable orifice in, and then use
the universal tool to turn in the adjustable
orifice one turn.
Monoject
Inspect and lubricate the air barrel
o’ring.
Monoject
Prepare the poppet by replacing the
seat and replacing/lubricating the
dynamic o’rings.
NOTE: Do not install the poppet/spring
or balance chamber into the air barrel
at this time.