732 RESPONSE TO THERMISTOR FAULT 234567 (2.7.21)
Table 183: Selections for parameter ID732
Selection
number
Selection name Description
0 No response
1 Warning
2
Fault, stop mode after fault
according to ID506
3
Fault, stop mode after fault
always by coasting
Setting the parameter to 0 will deactivate the protection.
733 RESPONSE TO FIELDBUS FAULT 234567 (2.7.22)
Set here the response mode for the fieldbus fault if fieldbus is the active control place. For
more information, see the respective Fieldbus Board Manual.
See parameter ID732.
734 RESPONSE TO SLOT FAULT 234567 (2.7.23)
Set here the response mode for a board slot fault due to missing or broken board.
See parameter ID732.
738 AUTOMATIC RESTART: NUMBER OF TRIES AFTER UNDERLOAD FAULT TRIP (2.8.10)
This parameter determines how many automatic restarts can be made during the trial time
set by parameter ID718.
Table 184: Selections for parameter ID738
Selection
number
Selection name Description
0
No automatic restart after
Underload fault trip
>0
Number of automatic restarts
after Underload fault trip