EasyManua.ls Logo

Vacon NXP series - Page 287

Vacon NXP series
392 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
A B
50%
50%
From reverse to forward
From forward to reverse
Frequency reference
Hz
REVERSE
FORWARD
Joystick hysteresis,
ID384 = 20%
AI (V/mA)
(0-10V/20mA)
Par. ID322
= 90%
f
min
ID101 =
Ref. scaling min
ID303 = 0 Hz
f
max
ID102
= 50 Hz
Reference
scaling max
ID304 = 70 Hz
Par. ID321
= 20%
Fig. 58: An example of joystick hysteresis. In this example, the value of parameter ID385 (Sleep
limit) = 0
385 AI1 SLEEP LIMIT 6 (2.2.2.9)
The AC drive is stopped if the AI signal level falls below the Sleep limit defined with this
parameter. See also parameter ID386 and Fig. 59.
A B
50%
50%
From reverse to forward
From forward to reverse
Frequency reference
Hz
REVERSE
FORWARD
Joystick hysteresis,
ID384 = 20%
AI (V/mA)
(0-10V/20mA)
Par. ID322
= 90%
Sleep limit
ID385=7%
START
START
STOP
STOP
f
min
ID101 =
Ref. scaling min
ID303 = 0 Hz
f
max
ID102
= 50 Hz
Reference
scaling max
ID304 = 70 Hz
Par. ID321
= 20%
Fig. 59: Example of sleep limit function
PARAMETER DESCRIPTIONS VACON · 287