EasyManua.ls Logo

Vaisala AWS310-SITE - Runway Temperature Message for Avimet

Vaisala AWS310-SITE
176 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Example of Soil Temperature 2 Message
<SOH>TS2<STX> 12.9 E834<ETX><CR><LF><EOT>
4.11.13 Runway Temperature Message for AviMet
Runway Temperature Message Format
<SOH>TR1<STX> xxx.x <CRC16 %04d><ETX><CR><LF><EOT>
Name
Description
<SOH>TR1<STX>
Message header
xxx.x
Runway temperature (C), 1minute average
<CRC16 %04d>
Message checksum:
Checksum span = Includes header, until checksum
<ETX><CR><LF><EOT>
Message trailer
Runway Temperature Message Characteristics
Property
Value
Default send interval 60 s
Polling command
TRREP
If there is no runway temperature data available, the message is substituted with the
following:
TR data missing<CR><LF>
Example of Runway Temperature Message
<SOH>TR1<STX> 25.8 26FB<ETX><CR><LF><EOT>
AWS310-SITE Configuration and Maintenance Manual M211828EN-C
72

Table of Contents

Other manuals for Vaisala AWS310-SITE

Related product manuals