EasyManua.ls Logo

Vaisala HMDW110 - Table 7 Errs Command; Table 8 Error Messages on ERRS Command

Vaisala HMDW110
92 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Syntax Description
Example:
?
HMDW110 / 1.0.6
Serial number : H0134007
Batch number : H0130002
Sensor number : H0090003
Sensor model : Humicap 180R
Order code : HMD1102A1VA1
Cal. date : 20140619
Cal. info : VAISALA/HEL
Time : 01:43:43
Serial mode : STOP
Baud P D S : 19200 N 8 1
Output interval: 5 S
Serial delay : 25
Address : 0
Filter : 1.000
Ch1 output : 4 ... 20 mA
Ch2 output : 4 ... 20 mA
Ch1 RH lo : 0.00 %RH
Ch1 RH hi : 100.00 %RH
Ch2 T lo : -40.00 'C
Ch2 T hi : 60.00 'C
Table 7 Errs Command
Syntax Description
errs<cr> Show active error(s). Possible error messages
are listed in Error Messages in Insight Software
(page 70).
Example (no active errors):
errs
0000h
No errors
Table 8 Error Messages on ERRS Command
ERRS Command Response Corresponding Error
T MEAS error
Temperature measurement error. [44]
F meas error
Humidity measurement error. [45]
RH sensor failure
Humidity sensor failure. [46]
Frequency measurement outside the
permissible value range
Capacitance reference error. [47]
HMDW110 User Guide M211726EN-D