Characteristic Description
Non-operating environment Temperature: -40 ... 70° C (-40 ... 156° F)
Humidity: 10 ... 95% @ 60° C, non-condensing
Vibration (5 ... 500Hz): 2 G
Operating environment Temperature: 0 ... 40° C (32 ... 122° F)
Humidity: 10 ... 95% @ 40° C, non-condensing
Vibration (5 ... 500Hz): 1 Grms
Shock: 10 G (with 11 ms duration, half sine wave)
Physical characteristics Dimensions (W * H * D): 426.4 * 132.2 * 480 mm (16.79" * 5.2" * 18.9")
Weight: 12 kg
Power Dual redundant power supplies auto-ranging 100 ... 240V AC
More Information
RVP902 Signal Processing Computer (page 36)
Installing RVP902 Main Chassis (page 73)
9.7 RVP902 Safety Compliance
Table 83 RVP902 Safety Compliance
Item Standard
Radiated and
Conducted Emissions.
FCC Part 15 Class A
ICES-003, AS/NZS & CISPR32
EN55011 Class A Group 1
Harmonics and Flicker EN61000-3-2 & 3-3
Electromagnetic
compatibility
EN61000-6-2 - 2005
ESD EN61000-4-2
Radiated Immunity EN61000-4-3
EFT / Burst EN61000-4-4
Surge EN61000-4-5
Conducted
Susceptibility
EN61000-4-6
Dips / Dropouts EN61000-4-11
Product Safety CE Mark - EN60950-1
Chapter 9 – Technical Data
335