EasyManua.ls Logo

Valmet K17122 User Manual

Valmet K17122
95 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Valmet Microwave Consistency
Measurement - Valmet MCA
Installation, Operating
& Maintenance
K17122 V1.1 EN

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Valmet K17122 and is the answer not in the manual?

Valmet K17122 Specifications

General IconGeneral
BrandValmet
ModelK17122
CategoryIndustrial Equipment
LanguageEnglish

Summary

1 Recycling and Disposing

2 Warnings & Safety Information

Safety Cautions and Dangers

Caution regarding hot sample lines and dangers of incorrect electrical connections or welding.

3 About the Sensor

3.1 Sensor Models

Describes the different Valmet Microwave Consistency Measurement (Valmet MCA) sensor models.

3.2 Measurement Principle

Explains the working principle of the sensor based on microwave propagation time.

4 Structure

4.1 FT Sensor Model Structure

Describes the physical structure and components of the FT sensor model.

4.2 TB Sensor Model Structure

Describes the physical structure and components of the TB sensor model.

4.3 Sensor Electronics

4.4 Valmet BRIDGE

5 Installation

5.1 Choosing the Sensor Model

Guidelines for selecting the appropriate sensor model based on pipe size and flange standards.

5.2 Choosing the Installation Site

Requirements and considerations for selecting the optimal installation location for the sensor.

5.3 Installation Checklist

6 Installation, FT Model

6.1 FT Model Installation Locations

Illustrates recommended and prohibited installation sites for the FT sensor model.

6.2 FT Sensor Dimensions (DN50/2")

FT Sensor Dimensions (FT80, FT100, FT150, FT200)

FT Sensor Dimensions (FT250, FT300)

6.3 FT Model Mounting Dimensions

7 Installation, TB Model

7.1 TB Model Installation Locations

Illustrates recommended and prohibited installation sites for the TB sensor model.

7.2 TB Sensor Dimensions

7.3 TB Model Process Coupling

TB Model Installation Position

7.4 Mounting Clamp (TB Model)

8 Operating Terminal

8.1 Mechanical Installation

Instructions for mechanically mounting the operating terminal, considering vibration and height.

8.2 Electric Connections

Customer Connections for Operating Terminal

8.3 Current Output Connections

8.4 Binary Input Connections

8.5 Binary Output Connections

8.6 Connecting the Sensor Cable

9 Setting Up

9.1 Mechanical Inspection

Checks for delivery content and device integrity after transport.

9.2 Installing Sensor and Operating Terminal

Guidance on installing the sensor and operating terminal, with a warning about high voltage.

9.3 Cabling Inspection

Checks for correct power, current output, and sensor cable connections.

9.4 Electrical Inspection

Checks electronics connection to power and selection switch position.

9.5 Quick Setup

10 Operating

10.1 Main User Interface

Overview of the main user interface panels: control, menu, main view, and status.

10.2 Virtual Keyboard

10.3 Menu Map

11 Configuration

11.1 General Settings

Configuration of general device settings like timezone and time.

Interface: User Interface Settings

11.2 Connection Settings

Binary Inputs Configuration

Binary Outputs Configuration

11.3 Sensor Settings

11.4 User Information

11.5 Trend Settings

12 Calibration

12.1 Recipes

Explanation of the Recipe function for managing different measurement conditions.

Editing Recipes

12.2 Sample Taking

Stopping Sample Taking

12.3 Entering Laboratory Values

12.4 Calibration View

Single Point Calibration

Multi Point Calibration

Manual Gain and Offset Correction

Calibration Result Display

12.5 Calibration and Sample History

13 Advanced Calibration

13.1 When to Use Advanced Calibration

Explains situations where advanced calibration is needed for precise measurement tuning.

13.2 Chemical Compensation

13.3 Temperature/Pressure Compensation

13.4 Manual Compensation

2nd Degree Adaptation

1st Degree (Linear) Adaptation

14 Diagnostics

14.1 Trend

Monitoring online measurement sampling, sequences, alarms, and errors via graphs.

Saving Trend Log

14.2 Event Log

14.3 Diary

14.4 Measurement Values and Limits

15 Troubleshooting

15.1 Detecting Sources of Problems

Identifies common issues like air, chemicals, temperature, antenna contamination, and sensor electronics failures.

15.2 Diagnostic Messages

Failsafe Signals Overview

Error and Warning Signals

16 Maintenance

16.1 Current Loop Test

Performing tests on current outputs by setting them to test mode.

16.2 Sensor Measurement Tuning

Adjusting sensor-specific parameters for optimal measurement performance.

16.3 Sensor Self Test

16.4 Reset Functionality

17 Replacing Parts

17.1 Sensor Electronics (TB, FT)

Step-by-step instructions for removing and installing sensor electronics for TB and FT models.

Installing Sensor Electronics

17.2 Antenna Cables (TB)

Removing TB Antenna Cables

Installing TB Antenna Cables

Installing TB Antenna Cables (Continued)

17.3 Temperature and Pressure Sensors (TB)

Installing Temperature Sensor

Installing Pressure Sensor

17.4 Measurement Head (TB)

Installing Measurement Head (TB)

17.5 Antenna Cables (FT)

Removing FT Antenna Cables

Installing FT Antenna Cables

17.6 Temperature and Pressure Sensors (FT)

Installing Temperature/Pressure Sensors (FT)

FT Antenna Replacement

18 WEEE Information

Valmet MCA Technical Specification

Valmet MCA Spare Parts

Valmet BRIDGE Technical Specification

Valmet BRIDGE Spare Parts

EU Declaration of Conformity

Related product manuals