INSTALLATION
Series 612
Edition 2013-04-12
601894EA
Setup function
Command
Acknowledgement
(within 10ms after reception of command)
Description
SENSOR
CONFIGURATION
Set
[s:01][abcdefgh][CR][LF]
[s:01][CR][LF]
Get
[i:01][CR][LF]
[i:01][abcdefgh][CR][LF]
data length 8 characters
a 0 = no sensor
1 = 1 sensor operation (sensor 1 input)
2 = 2 sensor operation with automatic changeover
(low range = sensor 2 input, high range = sensor 1 input)
3
= 1 sensor operation (sensor 2 input)
4
= 2 sensor operation with automatic changeover
(low range = sensor 1 input, high range = sensor 2 input)
Note: Sensor operation modes 2, 3 and 4 are possible with 2 sensor
hardware (612 . . - . . . H - . . . . and 612 . . - . . . W - . . . .) only.
Note: For applications where the high range sensor is used for for monitoring
purpose only, select sensor operation modes 1 or 3 for pressure control with
low range sensor and read high range sensor from «SENSOR 2 READING»
resp. «SENSOR 1 READING».
b 1 = ZERO enabled, 0 = ZERO disabled
cdefgh High range / Low range sensor full scale ratio * 1’000 (1000 100000).
In case of a 1 sensor valve use any value within the valid range.
This function does the sensor configuration for pressure control.