MAINTENANCE Series
65
112/129
Edition 2019-05-03 963283EA
Description
Required tool
19. Remove actuator shaft seals
carefully with a soft tool.
20. Clean actuator feedthrough with
alcohol.
21. Lubricate each o-ring groove with
0.1 ml vacuum grease. Pay attention
that grease is distributed constantly
over the whole circumference.
Soft tool
(o-ring remover)
Vacuum grease
22. Clean or replace seals if necessary.
Lubricate each o-ring with 0.05 ml
vacuum grease.
23. Install o-rings.
24. Deposit 0.1 ml vacuum grease on
each o-ring. Pay attention that
grease is distributed constantly over
the whole circumference.
Vacuum grease
25. Remove fixation kit and mounting
screw for pendulum plate.
26. Clean screw and slightly lubricate
thread. Then reinstall fixation kit.
27. Clean actuator shaft and lubricate it
with 0.1 ml vacuum grease.
Vacuum grease
28. Install actuator
Tighten actuator screws with
10 Nm.
Remove vacuum grease from
actuator shaft face after
installation.
Allen Wrench
5mm