EasyManua.ls Logo

Vechline 0115233 - Troubleshooting Common Issues; Error Code Diagnostics

Vechline 0115233
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
34
POSSIBLE PROBLEMS AND SOLUTIONS
Problem
Possible cause
Solution
The device is not working
1.
Has the main switch been
turned off?
1.
Turn on the main power supply.
2.
Has the power been turned
off?
2.
Check if other electrical devices are
working.
3.
Is the inlet or outlet gate
blocked?
3.
Check the inlet or outlet port for
obstruction.
4.
Is the fuse broken?
4.
Have a specialist replace the fuse.
5.
Is the voltage too low?
5.
Check the input voltage.
The air conditioner does not
blow cold air
1.
What mode is the air
conditioning in?
1.
Reboot and wait 3 minutes / select
cooling mode.
Result is not cool enough
1.
Has the desired
temperature been set
correctly?
1.
Set the desired temperature differently.
2.
Is the filter clogged or is
there dirt in the filter?
2.
Clean the filter well.
Unclear noises and
vibrations
1.
Are the units unstable or on
a sloping surface?
1.
Place the units on a flat surface.
2.
Is there dust near the fresh
air outlet?
2.
Clean the filter.
The air conditioning is equipped with a self-checking function. Below you will find possible
error messages and the measures to be taken in this case.
Error code
Problem
Cause and action
E0
Too much sewage.
Drain the excess water through the hose on the back of the
indoor unit until it is empty.
E1
Indoor temperatur Sensor
Error in the temperature sensor. Please contact the
importer.
E2
EVA-Sensor
Error in the EVA sensor. Please contact the importer.
E7
Overcooling
Check the coupling cable between the two units and
reconnect it if necessary. If no result is obtained, please
contact the importer.