Instruction Manual PEL-4 Precision LED Sector Light Vega Industries Ltd Aug 2018
PEL-4 Precision LED Sector Light Page 17 of 69 Manual Version V1.06
accepted the PEL-4 will provide the
voltage level in a series of flashes
(12.3VDC). One quick flash followed by a
0.5sec gap followed by 2 quick flashes
followed by a 0.5 second gap followed by
two quick flashes.
3. Exit programming mode
Leave the programmer idle for 10
seconds
The PEL-4 will give two quick flashes
followed by a short pause followed by
another two quick flashes.
After this the PEL-4 will resume normal
opera
tion.
4.5 Deciding which Settings are required
Since the PEL-4 is delivered from the factory with operator-specified settings, it is unlikely
to be necessary to reprogram any settings. The “Read Settings” feature can be used to
note the values already programmed.
4.6 Programming or Reading Multiple Settings
In the examples above, the PEL-4 was allowed to time-out of programming mode after
reading or writing each parameter. This is not necessary as multiple parameters can be
read and written in one programming sequence.