Instruction Manual PEL-4 Precision LED Sector Light Vega Industries Ltd Aug 2018
PEL-4 Precision LED Sector Light Page 42 of 69 Manual Version V1.06
Appendix A.3 Factory Default Reset Commands
The following commands reset multiple beacon settings to nominal values. Several
alternative commands are provided for convenience, allowing a beacon to be set to one of
several nominal operational types. For a particular factory reset programming code, the
beacon is programmed with the settings in the same row as the code.
Programming
Reset
Reset Effects
1-5-999
<FDF>999/
Oscillating
Boundary
+
12V Battery
Thresholds
Default (Night & Day) Fixed Character (1-0-000)
Night intensity is set to maximum intensity
Day intensity is set to maximum intensity
Master sync & zero sync delay set (1-3-000)
IALA day/night thresholds (1-4-005)
Normal, Automatic Best Effort Mode (1-5-002)
Standard sync behaviour (1-7-999, 1-7-002)
Low and high battery thresholds reset to 12V
nominal. These should be reviewed by the user
and adjusted for the supply voltage if
necessary.
Default Effective Intensity Flash Mode & Single
Flash Character Modes (7-2-000)
Auto-storage and calendar modes are disabled.
Oscillating boundary detection and alarm
function are enabled.
Remote control and traffic light modes are
1-5-998
<FDF>998/
Fixed
Boundary
+
24V Battery
Thresholds
Default (Night & Day) Fixed Character (1-0-000)
Night intensity is set to maximum intensity
Day intensity is set to maximum intensity
Master sync & zero sync delay set (1-3-000)
IALA day/night thresholds (1-4-005)
Normal, Automatic Best Effort Mode (1-5-002)
Standard sync behaviour (1-7-999, 1-7-002)
Low and high battery thresholds reset to 24V
nominal. These should be reviewed by the user
and adjusted for the supply voltage if
necessary.
Default Effective Intensity Flash Mode & Single
Flash Character Modes (7-2-000)
Auto-storage and calendar modes are disabled.
Oscillating boundary detection and alarm
function are disabled.
Remote control and traffic light modes are