24
5 Connecting to power supply
POINTRAC 31 • 8/16 mA/HART - four-wire
43388-EN-180322
Information:
The terminal blocks are pluggable and can be detached from the
electronics. To do this, loosen the two lateral locking levers of the
terminal block with a small screwdriver. When loosening the locking,
the terminal block is automatically squeezed out. It must snap in place
when re-inserted.
5.2 Connection
Non-Ex instruments and instruments with non-intrinsically safe
current output
1
1
24
/L
/N
PE
56 91011
22
11
12
2122 1920 18 17 14 1316 15 12
2
3
1
4
6
5
Fig. 10: Electronics and terminal compartment with non-Ex instruments and
instruments with non-intrinsically safe current output
1 Voltage supply
2 Relay output
3 Signal output 8/16 mA/HART active
4 Signal output 8/16 mA/HART Multidrop passive
5 Interface for sensor-sensor communication (MGC)
6 Setting the bus address for sensor-sensor communication (MGC)
2)
567
8
2
1
Fig. 11: Adjustment and connection compartment with non-Ex instruments and
instruments with non-intrinsically safe current output
1 Terminals for the external display and adjustment unit
2 Contact pins for the display and adjustment module or interface adapter
Electronics and terminal
compartment - Non-Ex
instruments and instru-
ments with non-intrinsi-
cally safe current output
Adjustment and con-
nection compartment
- Non-Ex instruments and
instruments with non-
intrinsically safe current
output
2)
MGC = Multi Gauge Communication