Provides information on mounting, connection, setup, maintenance, and safety.
Manual is for trained specialist personnel.
Explains symbols like Information, Caution, Warning, Danger, Ex, SIL, List, Action, Sequence, and Battery disposal.
Operations must be performed by trained personnel authorized by the plant operator.
Used for measured value indication of 4...20 mA circuits.
Incorrect use can cause hazards, damage to property, persons, or environment.
Instrument must be operated in a flawless condition, user is responsible for compliance with safety rules.
Safety markings, EU conformity, NAMUR recommendations, and environmental instructions.
Lists scope of delivery: display, mounting material, documentation, safety instructions.
External display for 4...20 mA circuits, HART-transparent, no external power required.
5-digit LC display, bar graph, unit indication, adjustment via three keys.
Details packaging standards, transport considerations, inspection, and storage conditions.
Specifies horizontal installation, panel cut-out dimensions, and max panel thickness.
Steps for inserting the instrument, attaching clips, and tightening rods.
Safety instructions, voltage supply requirements, and using spring-loaded terminals.
Shows terminal assignment on the rear of the housing.
Details terminal functions, polarity, notes, and function ground connection.
Wiring plan for connecting VEGADIS 176 to passive sensors.
Wiring plans for passive sensors with backlight, active sensors, and instruments with backlight.
Illustrates connection examples for 4...20 mA sensors and instruments.
Illustrates connection to signal conditioning instruments or four-wire sensors.
Describes the self-check sequence upon power-up and initial display.
Identifies display elements, symbols, and adjustment keys.
Explains the menu structure for setup and parameter adjustment.
Configuration of decimal places, scaling for 4mA and 20mA values, and units.
Accesses diagnostic messages (Actual Error, Last Error) and firmware version.
Provides expert settings, including user code and factory reset options.
Configuration of user code, factory reset, linearization, NAMUR, range limits, and offset.
No special maintenance, but lists causes of malfunction like sensor, process, or signal issues.
Steps to check signal, handle error limits (NAMUR NE 43), and sensor diagnosis.
Describes diagnostic codes for electronics modules, memory, calibration, and configuration errors.
VEGA service hotline contact and steps after fault rectification.
Steps for dismounting and information on proper disposal of the module according to WEEE directive.
General, ambient, and electromechanical data for the instrument.
Signal/supply circuit details, deviation, signal resolution, and electrical protective measures.
Information on instrument approvals and detailed dimensional drawings.
Details industrial property rights, trademarks, and company contact information.