6 Set up the sensor with the display and adjustment module
VEGAFLEX 81 • Modbus and Levelmaster protocol
42283-EN-140430
Display
Menu item Default value Modiedvalue
Language Order-specic
Displayed value 1 Filling height Level
Displayed value 2 Electronics temperature
Backlight Switchedo
Diagnostics
Menu item Default value Modiedvalue
Status signals - Function control Switched on
Statussignals-Outofspecication Switchedo
Status signals - Maintenance Switchedo
Device memory - Echo curve memory Stopped
Device memory - Measured value memory Started
Device memory - Measured value memory -
Measured values
Distance level, percentage value
level, reliability level, electronics
temperature
Device memory - Measured value memory - Re-
cording in time interval
3 min.
Device memory - Measured value memory - Re-
cordingwithmeasuredvaluedierence
15 %
Device memory - Measured value memory - Start
with measured value
Not active
Device memory - Measured value memory - Stop
with measured value
Not active
Device memory - Measured value memory - Stop
recording when memory is full
Not active
Additional adjustments
Menu item Default value Modiedvalue
PIN 0000
Date Actual date
Time Actual time
Time - Format 24 hours
Probe type Device-specic
The instrument settings are copied with this function. The following
functions are available:
•
Read from sensor: Read data from sensor and store into the
display and adjustment module
•
Write into sensor: Store data from the display and adjustment
module back to the sensor
Additional adjustments -
Copy instrument settings