88
10 Supplement
VEGAFLEX 81 • Modbus and Levelmaster protocol
42283-EN-140430
Error codes
Error Code Name
EE-Error Error While Storing Data in EEPROM
FR-Error Erorr in Frame (too short, too long, wrong data)
LV-Error Value out of limits
10.6 CongurationoftypicalModbushosts
Fisher ROC 809
Wiring plan
+
+
power supply
MODBUS
D0
D1
IS GND
USB
B
COM
Z
Y
A
(Rx/Tx -)
(Rx/Tx +)
1
2
3
45
2off
on
( )
( )
(-)
(-)
+8 +30
Vdc
to
GND
Fig.42:ConnectionofVEGAFLEX81toRTUFisherROC809
1 VEGAFLEX81
2 RTUFisherROC809
3 Voltage supply
Parameter
Parameter Value
Baud Rate 9600