11 Supplement
VEGAFLEX 86 • Probus PA
44232-EN-160518
Ʋ Ex 10
Electrical protective measures
Protection rating
Housing material Version IP-protection class NEMA protection
Plastic Single chamber
IP 66/IP 67 Type 4X
Double chamber IP 66/IP 67 Type 4X
Aluminium Single chamber IP 66/IP 68 (0.2 bar)
IP 68 (1 bar)
Type 6P
Type 6P
Double chamber IP 66/IP 67
IP 66/IP 68 (0.2 bar)
IP 68 (1 bar)
Type 4X
Type 6P
Type 6P
Stainless steel, electro-
polished
Single chamber IP 66/IP 68 (0.2 bar) Type 6P
Stainless steel, precision
casting
Single chamber IP 66/IP 68 (0.2 bar)
IP 68 (1 bar)
Type 6P
Type 6P
Double chamber IP 66/IP 67
IP 66/IP 68 (0.2 bar)
IP 68 (1 bar)
Type 4X
Type 6P
Type 6P
Protection rating (IEC 61010-1) III
Approvals
Instruments with approvals can have dierent technical specications depending on the version.
For that reason the associated approval documents of these instruments have to be carefully
noted. They are part of the delivery or can be downloaded under www.vega.com, "VEGATools"
and "Instrument search" as well as in the download area.
11.2 CommunicationProbusPA
Instrumentmasterle
The instrument master le (GSD) contains the characteristic data of the Probus PA instrument.
These data are, e.g. the permissible transmission rates as well as information on diagnostics values
and the format of the measured value outputted by the PA instrument.
A bitmap le is also provided for the Probus network planning tool. This le is installed automati-
cally when the GSD le is integrated. The bitmap le is used for symbolic indication of the PA instru-
ment in the conguration tool.
ID number
Each Probus instrument gets an unambiguous ident number (ID number) from the Probus user
organisation (PNO). This ID number is also included in the name of the GSD le. Optionally in ad-
dition to this manufacturer-specic GSD le, PNO also provides a general so-called prole-specic
GSD le. If the general GSD le is used, the sensor must be set to the prole-specic ident number
via the DTM software. By default, the sensor operates with the manufacturer-specic ID number.
When using the instruments on a segment coupler SK-2 or SK-3, no special GSD les are required.